BICITY ELECTRICALS & SERVICES

Jinko 4.8Kw 48v Jinko Lithium Battery JKS-B48100-HI

Jinko 4.8Kw 48v Jinko Lithium Battery JKS-B48100-HI

Jinko 4.8Kw 48v Jinko Lithium Battery JKS-B48100-HI is a low-voltage battery energy storage system based on a lithium iron phosphate (LFP) battery. It is one of the residential new energy storage products developed and produced by Jinko Solar Co., Ltd. This product can match most brand inverter protocols. It can be used with the inverter to effectively realize energy conversion and storage, solve the imbalance between distributed power generation and load, improve the stability and utilization rate of renewable energy generation, realize “ self-generation and self-consumption on the user side, and save electricity cost.

The excellent battery and BMS of this product can ensure a long cycle life.

Products Properties

  • Non-toxic, non-polluting, environmentally friendly and inner fireproof function
  • Long cycle life: 6000 cycles at 25
  • Good temperature performance
  • Full range of protection functions: over-voltage, under-voltage, short circuit, reverse connection, over-current, over temperature, equalization and overcharge, over-discharge
  • Easy to operate and maintain, integrated BMS design, self-remaining power management.

System Appearance and Performance Parameter

Model TypeJKS-B48100-HI
Physical Properties
Battery TypeLPF
Weight41 kg ± 2kg
Dimension (width × height × depth)442*430*130.5(± 2) mm
Altitude ≤2000m
Enclosure RatingIP20
Warranty Period10 years
Electrical Parameters
Rated Energy4.8kWh
Battery Capacity100 Ah
Usable Energy>4.5kWh
SOC operating range15% ~ 95%
Rated Voltage48 V
Maximum Short Circuit Current (fuse)100A
Operating Voltage Range30 V ~ 54.75 V
Internal Resistance ≤ 15 MΩ
Self-discharge rate/month≤3%(25°C)
Cycle Life6000@80% DOD. 70% EOL, 25°C
Working Parameters
Rated Charge and Discharge Current50A
Maximum Continuous Discharge Current 100A(1C)
Charging Temperature0 ~55°C
Discharging Temperature -20 ~ 60°C
Storage Temperature-10 ~ 30°C
Storage Humidity5% ~ 95%
Extended Parameters
Grouping Scheme1P15S
Capacity100Ah
Data CommunicationRS232/CAN/RS485
Cooling methodNatural cooling

Installation and Configuration

Installation Requirements

Working Temperature

Operating temperature range of this product: -20°C ~ 55°C and the optimal ambient temperature is 15°C ~ 30°C. Please note exceeding the operating temperature range will cause over/low temperature alarm or protection of the battery system which may reduce cycle life.

Working Environment

This product should be installed indoors and the site need to avoid the sun and be no wind, no conductive dust and corrosive gas

The installation location of the product should be away from the sea to brine and high humidity. The ground for product arrangement shall be flat band level and no flammable explosive or other materials around the product

Fire extinguisher System

For safety, the room must be equipped with a fire extinguishing system such as a portable dry powder fire extinguisher. The fire protection system needs to be inspected regularly to ensure it is in proper working condition.

Electrical interface check

Confirm whether the user’s PV device, or other power supply equipment has a DC output interface and measure whether the DC power output voltage meets the voltage range requirement in the table 2-1.1

Confirm that the max discharge current capacity of the DC power interface of the user’s PV device or other power supply equipment should be higher than the max charging current of the products used in the aforementioned table.

If the max discharge capacity of the DC power interface of the user’s PV device is less than the max charging current of the products used in table 2-1.1, the DC power interface of the user’s PV device shall have a current limiting function to ensure the normal operation of the user’s equipment.

Verify that the max operating current of the battery-powered user equipment (inverter DC input) should be less than the max discharge current of the products used in Aforementioned table.

Engineering Coordination

The power line specification shall meet the requirement of maximum discharge current for each product.

Make sure that the battery has enough room to install and that the brackets have enough load capacity.

Make sure the power line and ground wire are reasonable. Not easy to short-circuit, water and corrosion.

Unpacking Inspection

After the equipment arrives at the installation site, it should be loaded and unloaded according to regulations to avoid long-term sunlight or rain exposure. Before unpacking, the total number of packages should be indicated according to the shipping note attached to the package and the box should be checked for integrity

During the unboxing process, handle carefully to protect the surface coating of the item. Finally, read the documentation carefully before installation.

Battery Packing List

ItemSpecificationQuantity
JKS-B48100-HI 48V/100Ah1
Power cable positiveOrange/25mm2/L2000MMOptional: if you need longer please contact us
Power cable negativeOrange/25mm2/L2000MMOptional: if you need longer please contact us
Parallel cable positiveOrange parallel cable positive1
Parallel cable negativeBlack parallel cable negative1
Communication parallel cableGrey/L280mm/Double RJ45 plug1
Communication cable inverterBlack/L2000mm/Double RJ45 plug1
Ground wireL500mm, 4mm21
User ManualUser Manual1
4 PIN Terminal4 pin-3.811
Restart Pin/1
ScrewCombination screw M6*144
Factory Inspection Report/1
JKS-B48100-HI 
Jinko 4.8Kw 48v Jinko Lithium Battery JKS-B48100-HI
Power cable positive
Communication parallel cable
Communication parallel cable
Communication cable inverter
Communication cable inverter
Ground wire
Ground wire
Screw
Screw

Installation Procedure

Step 1PreparationConfirm that the MCB switch is in the “off state”
Step 2Mechanical InstallationDetermine the installation site of the battery
Battery Module installation
Step 3Electrical installationGround cable installation
Battery module parallel cable installation
Parallel communication cable installation
Step 4Battery system self-testTurn on the MCB switch
Press RESET button 6s to wake up the battery
Check the system output voltage and LED status
Shut down the system
Step 5Inverter connectingConnect the system power cable to the inverter
Battery system positive and negative cable installation
Connect master CAN IN communication cable to the inverter
Turn on the power switch and use RESET button to wake up the system
Turn on the inverter to check the communication between inverter and battery system

Battery parameter setting on the inverter

ItemParameter
Max charging (Bulk) Voltage54V
Absorption Voltage53.25V
Shut down (cut off) voltage43.25
Shut down  (cut off)  SOC20%
Restart Voltage44.25V
Max charge current50A
QTY Max discharge current50A*battery QTY

Get Jinko 4.8kWh Lithium Battery today.

Need Help? Chat with us!
Start a Conversation
Hi! Click one of our members below to chat on WhatsApp